Fetal Monitoring Intrepretation 2° Ed. - Librería Medica Distribuna

Fetal Monitoring Intrepretation 2° Ed.

COP $236.000
Impuestos incluidos

ISBN: 9781608313815
Autores: Cabaniss Micki, Ross Michael

Thoroughly updated for its Second Edition, Fetal Monitoring Interpretation describes and illustrates the full range of patterns revealed by fetal monitoring and explains their clinical significance. The book uses case studies and high-quality tracings

Formato
Cantidad
Últimas unidades en stock

>Gana 236 puntos/COP $11.800 Gana 236 puntos/COP $11.800 (Cada COP $1.000 gastado = 1 punto, 1 punto = COP $50 de descuento)
Tu carrito tendrá 236 puntos que podrán ser convertidos en un cupón de COP $11.800.

Medios de pago

MediosdePago.png

Thoroughly updated for its Second Edition, Fetal Monitoring Interpretation describes and illustrates the full range of patterns revealed by fetal monitoring and explains their clinical significance. The book uses case studies and high-quality tracings accompanied by detailed teaching diagrams usually found only in anatomical and surgical atlases. This edition includes twenty new case illustrations with teaching diagrams and five added tracings that present rare and unique patterns. The text incorporates the changes in terminology recommended by the 2008 workshop jointly sponsored by the National Institute of Child Health and Human Development, the American College of Obstetricians and Gynecologists, and the Society for Maternal-Fetal Medicine. Five new sections have been added:Pattern Transitions: Emphasizing the dynamic process of bedside assessment of the fetus, this section focuses on changes occurring over time, influenced by factors such as maternal health, pre-existing fetal health, gestation, and medications/anesthesia.Antepartum Monitoring: The first edition focused on intrapartum monitoring. The second edition presents a new section on the unique interpretation in the antepartum setting.Patterns Associated with Disease States and Other Conditions: For the first time, a section is included that begins with a maternal or fetal condition or the fetal environment and addresses potential fetal heart rate patterns that might be associated.Technology Behind Fetal Monitoring and Adjuncts to Fetal Assessment: This new section reviews adjunctive methods of fetal assessment that might improve on the monitor heart rate data in inconclusive situations.Medico-Legal Considerations: This section examines the role of the monitor in predicting or retrospectively assisting with the analysis of adverse neonatal outcomes and the future of the monitor in obstetrics

Tabla de contenido

Foreword Preface Acknowledgments 1.Introduction to the Fetal MonitorRole of the Electronic Fetal Monitor/Classification/Terminology/ Basic Review/National Institute of Child Health and Human Development Guidelines/Clinical Application/ Assessing Uterine Activity/Predicting the Oxygenated Fetus/Identifying the Oxygenated Compensated Fetus/Guiding Delivery Timing of the Fetus with Progressive Stress Despite Intervention/ Recognizing Abnormal Patterns Present from the Outset That Are Compatible with Possible Fetal Jeopardy, Possible Decompensation/Limitations/A Pattern Compatible with A Well-oxygenated Fetus in Labor Might Be Followed by a Poor Infant Outcome/A Fetus with a Pattern Associated with Decompensation Might Be Healthy at Birth/Fetuses with Remarkably Similar Fetal Monitoring Patterns Might Have Remarkably Different Outcomes2.Basic Pattern Components Bradycardia/Tachycardia/Variability/ Marked Variability: >25 beats per minute/Moderate Variability: 6 to 25 beats per minute/Minimal Variability: â ¤5 beats per minute/Absent Variability/Loss of Variability Associated with Sinus Node Suppression (as Opposed to Loss of Baseline/Variability/Role of Autocorrelation/Long-versus Short-Term Variability/Periodic and Nonperiodic Changes/Accelerations/Classic/Stimulation/Activity/Periodic Accelerations/Double-Form Accelerations/ Lambda Pattern/Late Accelerations/Prolonged Accelerations/ Marked Accelerations/Atypical Accelerations/No Variability in Accelerations Decelerations/Early Decelerations/Late Decelerations/Variable Decelerations/ Prolonged Decelerations3. Baseline Variants Sinusoidal and Other Undulating Patterns/Sinusoidal Variants/ Nonsinusoidal Variants/Baseline Shifts and Other Rate Aberrations/Rate Shifts/ Other Baseline Rate Aberrations4. Pattern Transitions Fetal Stress Dynamic ChangesOther Pattern Dynamics5. Uterine/Maternal-Fetal Activity Uterine Activity/Classic Contraction Waveform/Decreased Uterine Activity/Dysfunctional Uterine Activity/ Increased Uterine Activity/Maternal/Fetal Activity/Maternal Fetal6. Antepartum Monitoring Role of the Fetal Monitor in Fetal Welfare Assessment/Nonstress Test/ Nonstress Test as a Component of the Biophysical Profile/Contraction Stress Test/Other Methods of Fetal Welfare Assessment/Doppler/Fetal Movement Counting/Unique Interpretation in the Outpatient Setting/Baseline/Periodic and Nonperiodic Changes/Contractions7. Patterns Associated with Disease States and Other Conditions Maternal Conditions/Preeclampsia/Eclampsia/Hypertension/Diabetes Mellitus/Respiratory Disease/Maternal Cardiovascular Disease/ Intrahepatic Cholestasis of Pregnancy/ Pharmacologic Agents/Exercise/ Temperature AberrationAnemia/Trauma/ Advanced Age/Fetal Conditions/Preterm Gestation/Anomalies/Malpresentation/ Anemia/Infection/Twins/Intrauterine Growth Restriction/Postterm Gestation/ Support Structures/Umbilical Cord Conditions/Placental Conditions/ Amniotic Fluid Considerations/ Uterine Conditions/Second Stage and Delivery/Forceps Effects/Maternal Pushing Effects/Head Rotation Effects/ Descent Effects8. Dysrhythmias Sinus Node Variants/Sinus Bradycardia/Sinus Tachycardia/ Sinus Arrhythmia/Sinus Arrhythmia Marked/Respiratory Sinus Arrhythmia Marked with Premature Supraventricular Depolarizations/Sinus Pause with Junctional Escape/Sinus Arrest with Junctional Escape/Wandering Atrial Pacemaker/Long QT Syndrome/Dysrhythmias/ Tachyarrhythmias/Bradyarrhythmias/ Irregular Rates Produced by Premature Depolarizations9. Technology Behind Fetal Monitoring and Adjuncts to Fetal Assessment External Fetal Monitor Signal Processing 434 ArtifactsAbbreviated Table of Contents

Product Details

9781608313815

Ficha técnica

Año
2010
Editorial
Lippincott Williams
Páginas
512
Alto
28
Ancho
22
Edición
1
chat Comentarios (0)

Productos relacionados

X

WELCOME TO OUR WONDERFUL WORLD

Did you know that we ship to over 24 different countries

Login with Facebook
X

WELCOME TO OUR WONDERFUL WORLD

Did you know that we ship to over 24 different countries

Register with Facebook
X

WELCOME TO OUR WONDERFUL WORLD

Did you know that we ship to over 24 different countries

Please enter the email address you used to register. You will receive a temporary link to reset your password.